Releases: Gissio/radpro
2.1.1 "The dot mender"
By downloading this software, you agree to the Rad Pro terms and conditions.
Instructions:
- Use the update version if you have Rad Pro 2.1 installed.
- Use the install version if you have Rad Pro 2.0.3 or earlier installed.
Release Updates:
- Renamed "Conversion factor" to "Sensitivity" (as sensitivity is cpm/radiation rate, while conversion factor is radiation rate/cpm).
- Renamed the "GET tubeConversionFactor" data command to "GET tubeSensitivity".
- On 5-key devices, a short press of the power key in the measurement view now puts the display to sleep.
- On 3-key devices, holding the left and right keys in the measurement view now toggles pulse sounds.
- Lock mode can now be accessed from any screen without needing to navigate to the settings menu.
- Die rolls and coin flips now generate a single outcome per run.
- Added support for 100-sided and 10-sided die rolls, as well as binary random number generation.
- History is now calculated only when the instantaneous rate confidence interval falls below 75%.
- When the battery level is critically low (0 bars), Rad Pro now automatically saves the dose every 60 minutes.
Release Fixes:
- On devices with a color display, fixed an issue where the measurement dot occasionally failed to appear in the measurement view.
- Corrected battery voltage measurement issues on the Bosean FS-5000.
2.1 "Delicious trifles"
By downloading this software, you agree to the Rad Pro terms and conditions.
This release requires an installation.
Release updates:
- Added the ability to dismiss alarms with the reset measurement key.
- Added configurable alarm signaling: sound, vibration, pulse LED and display flash.
- Added an alarm enabled indicator.
- Implemented a keyboard lock mode, accessible from Settings.
- Display of dose counts below 10000 now shown in standard notation.
- Added new rate and dose alarm options.
- Added new average timer options.
- Extended the dead-time compensation range to 20-320 µs.
- Added the ability to toggle pulse sounds from the measurement view on supported devices.
- Added a new pulses chirps sound option.
- Extended the duration of alarm sounds.
- Enhanced the menu structure for more intuitive navigation.
- Updated the UI font to Open Sans for enhanced readability.
- Minor UI improvements.
Release fixes:
- On color displays, fixed an issue causing an unsightly flash when waking from sleep mode.
- Fixed alarms continuing to sound after device shutdown while connected to external power.
- Corrected the display of secondary rate and count views after the average timer expired.
- Resolved an issue where the device state wasn't reset after a quick power cycle.
- Corrected a problem where 1 minute instantaneous averaging at high radiation levels didn't average correctly.
2.0.3 "The sensitive update"
By downloading this software, you agree to the Rad Pro terms and conditions.
This release requires an installation.
Release notes:
- Extended conversion factor range to 25-12800 cpm/µSv/h.
- When using sensitive detectors with a conversion factor of 600 cpm/µSv/h or higher, pulse indication is now capped at 600 cpm/µSv/h to provide approximately one pulse per second at background levels of radiation. This does not impact the actual measurements.
- Minor UI and performance refinements.
- Added the Rad Pro simulator.
2.0.2 "The precise release" (flashtool v2)
By downloading this software, you agree to the Rad Pro terms and conditions.
Instructions:
- Use the update version if you have Rad Pro 2.0.1 installed.
- Use the install version if you have Rad Pro 2.0.0 or earlier installed.
Release notes:
- Improved the instantaneous rate averaging algorithm.
- Simplified the instantaneous rate averaging response curves, resulting in improved precision when using J613/J614 tubes.
- Disabled instantaneous rate alarms in situations where the confidence interval is high, such as immediately after device startup.
- Minor UI improvements.
- Fixes an error in the flashtool (with FNIRSI GC-01 devices).
2.0.1 "Nobody's perfect"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Added data log reset.
- Changed the default conversion factor for J613/J614 tubes to 60.0 cpm/µSv/h.
- Resolved issues with custom HV profiles.
- Resolved issues with the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests.
- Resolved issues with new history data log download.
- Minor refinements.
2.0 "Grand première"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- First 2.0 release.
- Updated the UI design system to OpenBridge 5.0, improving legibility under sunlight.
- Changed the default conversion factor for J613/J614 tubes to 30.0 cpm/µSv/h.
- Removed the FNIRSI GC-01 display panel settings.
- Increased the granularity and range of the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests to 100 Hz-100 kHz and 0 %-100 %, respectively (not stored on power-off).
2.0rc5 "The final countdown"
By downloading this software, you agree to the Rad Pro terms and conditions.
On FNIRSI GC-01 devices, make sure you select the correct display panel in display settings!
Notes:
- Added Bosean FS-5000 support.
- Added display panel menu for selecting the display panel (on supported devices).
- Added secondary dose view in average measurement mode.
- Extended conversion factor range to 25-1600 cpm/µSv/h.
- Added 1 second datalog interval options and removed 30 seconds and 30 minutes datalog interval options.
- Added "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection commands.
- Added 12-hour time format.
- Devices with data mode allow using the device while data mode is active; data mode state is also preserved after powering off.
- Improved battery level indicator of the Bosean FS-600/FS-1000.
- Improved battery level readout of the FS2011(STM32F051), Bosean FS-600/FS-1000.
- Improved keyboard control scheme of the Bosean FS-1000.
- Changed USB data connection end of line to "\r\n".
- Minor refinements.
2.0rc4 "The little update"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
- Added secondary CPM and count displays in measurement views.
- Improved haptic pulse strengths.
- Improved FNIRSI GC-01 quiet pulse clicks.
- Improved selected menu item contrast.
- Improved datalogging time precision.
- Fixed History (24 h) bug.
2.0rc3 "The BIG update"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- UI update with BIG numbers.
- Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
- History alert zones (1 µSv, 10 µSv).
- Average timer expiration after reaching a configurable confidence interval.
- Background compensation.
- Display flashes on the FNIRSI GC-01 (after display sleep).
- Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
- Pulses threshold (disables pulse indication if instantaneous rate is below a certain value).
- Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
- Added 30 second and 10 second datalog interval options.
- Added 10 second display sleep option.
- Added
radpro-flashtool
. - Removed hold option.
2.0rc2
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Changed default display theme to Dusk.
- Fixed flash programming code.
- Fixed FNIRSI GC-01 battery indicator.
- Fixed conversion factor menu logic.