Skip to content

I simulated thermodynamics of the Rankine cycle for a 55 megawatts actual power plant with wet cooling tower

Notifications You must be signed in to change notification settings

arashbaj/Steam-powerplant-

Repository files navigation

Results Checked with actual Tests in the powerplant. we tested it in 4 conditions: first in full load condition with 100 percent steam injection. then we tested 75 and 125 percent steam injection. then we tested it in summer condition with ambient temperature of 42 degrees. for more information contact me: arashbaj1992@gmail.com

About

I simulated thermodynamics of the Rankine cycle for a 55 megawatts actual power plant with wet cooling tower